According to SCTE- and NCTA-recommended trunk system map symbols, fiber-optic cable is represented by - Double arrows within a small circle on a solid line.
The forward path signal in a traditional tree-and-branch architecture - Originates at the headend and is transmitted downstream through...
Progression: Maintenance Tech I - II
Conventional NCTI 2020
According to SCTE- and NCTA-recommended trunk system map symbols, fiber-optic
cable is represented by - ✔ Double arrows within a small circle on a solid line.
The forward path signal in a traditional tree-and-branch architecture - ✔ Originates at
the headend and is transmitted downstream through coaxial trunk cable and trunk
amplifiers.
In an HFC network, - ✔ Processing equipment in the headend converts the forward RF
signal to a light signal.
During aerial plant construction, - ✔ The strand is tensioned so its sag profile matches
that of the overhead utility power lines.
With underground plant construction, - ✔ The fiber-optic and coaxial cables are often
placed underground with other utility lines to jointly share construction costs.
Standby power supplies - ✔ Continue providing an output voltage even during a utility
power outage by using a backup power source.
Centralized power configurations - ✔ Provide the advantage of increased reliability
through sharing of expensive backup generators and sophisticated monitoring
equipment among different power realms.
When transmitting broadband signals - ✔ In a two-way hybrid fiber/coax (HFC)
network, two or more individual optical fibers are required for each optical node location.
RF trunk amplifiers - ✔ Have attenuator pads, equalizers, and diplex filters that control
and route the RF signals.
Verifying plant reliability includes - ✔ Frequency response sweeping, which is adjusting
RF amplifier circuits to amplify all frequencies in the bandpass spectrum as equally as
possible
Which of the following is a requirement in the process for measuring leakage using a
dipole antenna, as required by the FCC? - ✔ The antenna must be placed 3 meters
from the system components and 3 meters from the ground.
Many cable companies require which type of leaks to be fixed? - ✔ All types of leaks
must be fixed.
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper academicmaster. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €15,01. Je zit daarna nergens aan vast.