IBC EXAM PREP UPDATED Exam Questions and CORRECT Answers the shear capacity for horizontal wood frame gypsum board diaphragm ceiling is how many POF for gypsum board 1/2 inch thick with 16 on Center spacing of - Correct Answer- 90 plf in exterior plaster, a minimum of 0.019 of an inch number ...

[Meer zien]

Voorbeeld 2 van de 11  pagina's

  • 25 augustus 2024
  • 11
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
Alle documenten voor dit vak (26)
avatar-seller
MGRADES
IBC EXAM PREP UPDATED Exam
Questions and CORRECT Answers

the shear capacity for horizontal wood frame gypsum board diaphragm ceiling is how many
POF for gypsum board 1/2 inch thick with 16 on Center spacing of - Correct Answer- 90 plf


in exterior plaster, a minimum of 0.019 of an inch number 26 galvanized galvanized sheet
gauge corrosion resistant weep screed with a minimum vertical attachment flange of what
must be provided at or below the foundation plate line on exterior wall studs - Correct
Answer- three and a half inch


in exterior plaster, the weep screed must be placed a minimum of how many inches above the
Earth or 2in above paved areas how many inches must weep screed be placed above - Correct
Answer- 4 inches


what is the minimum time. For moist curing between the first and second cement plaster code
in an exterior application how many hours? - Correct Answer- 48


what is a minimum thickness of reinforced gypsum concrete how many inches? - Correct
Answer- 2 inch


what is the maximum flame spread index of foam plastic insulation used as interior wall or
ceiling finish? Which section is this located in - Correct Answer- 75 flame spread index,
located in section 2603 foam plastic insulation


what is the minimum density of interior plastic trim how many PCF which section is this
located in? - Correct Answer- 20 PCF 320 kg in section 2604 interior finish and trim chapter
26 Plastics


what is a Max flame spread index of foam plastic insulation used as interior wall or ceiling
finished - Correct Answer- 75


what is the minimum density of interior plastic trim PCF? - Correct Answer- 20 PCF

, blank? Is masonry in which the tensile resistance of the masonry is taken into consideration
and the effects of stresses in reinforcements are neglected what type of Masonry? - Correct
Answer- plain Masonry


pre-stress masonry is masonry in which internal stresses have been introduced to counteract
potential? Stresses in masonry resulting from applied loads. compressive? Sheer? Tinsel? -
Correct Answer- tinsel


the center of gravity of projecting masonry or molded cornices must lie within the middle of?
Of the sporting wall. one third? 1/2? 2/3? - Correct Answer- one third


the total minimum thickness of front, back and side walls of a smoke chamber walls must be
how many inches of solid Masonry? - Correct Answer- 8 in


fireplace Hurst must have a minimum thickness of? Inches - Correct Answer- 4 in


in fireplace installations, spaces between wood joists, beams or headers must be fireblock to a
depth of? - Correct Answer- 1 inch


chimneys must extend a minimum of how many feet higher than any portion of the building
within 10 ft? - Correct Answer- 2 feet


chimney flues that are connected to more than one Appliance, one must not be less than the
area of the largest connector Plus what percentage of the area's additional chimney
connectors? - Correct Answer- 50%


what is the minimum air space clearance required between masonry chimneys located in the
interior of a building and combustibles components how many inches? - Correct Answer- 2 in


where masonry chimneys are constructed as part of a masonry or concrete walls, combustible
materials must not be in contact with the masonry or concrete wall less than? How many
inches from the inside surface of the nearest flue lining? - Correct Answer- 12 in


a collector is a horizontal diaphragm element? And in line with the applied force that collects
and transfers diaphragm Shear forces to the vertical elements of the lateral Force resisting
system or distributes forces within a diagram or both - Correct Answer- parallel

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper MGRADES. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €9,88. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 67474 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€9,88
  • (0)
  Kopen