Avnrt - Samenvattingen, Aantekeningen en Examens

Op zoek naar een samenvatting over Avnrt? Op deze pagina vind je 105 samenvattingen over Avnrt.

Alle 105 resultaten

Sorteer op

IBHRE CEPS - Trouble Questions & Answers 2023/2024
  • IBHRE CEPS - Trouble Questions & Answers 2023/2024

  • Tentamen (uitwerkingen) • 11 pagina's • 2023
  • IBHRE CEPS - Trouble Questions & Answers 2023/2024 168. Compared to the the permanent pacemaker, does a temp pacer have constant current or voltage? Also, how much voltage can it generate? 5V or 20V? - ANSWER-Constant current, 20V. (Doubles 9.5V) 171. Which patient with acute MI is most likely to need a temp pacer? Inferior MI, Mobitz I AV Bock Inferior MI, bundle branch block Anterior MI, Mobitz I AV Bock Anterior MI, bundle branch block - ANSWER-Anterior MI, bundle branch block A...
    (0)
  • €9,26
  • 3x verkocht
  • + meer info
AAH EKG practice exam questions & answers 2024/2025
  • AAH EKG practice exam questions & answers 2024/2025

  • Tentamen (uitwerkingen) • 7 pagina's • 2024
  • AAH EKG practice exam questions & answers 2024/2025 Leads II, III AVF view what portion of the heart? Septal Anterior Inferior Lateral - ANSWERSInferior Which of the following ECG leads are bipolar leads? I, II, III I and AVL I, II, AVR II and AV - ANSWERSI, II, III The most common type of supraventricular Tachycardia is: Atrial flutter AV nodal Reentrant tachycardia (AVNRT) Atrial fibrillation AV Reentrant Tachycardia (AVRT) - ANSWERSAV nodal Reentrant tachycardia (AVNRT)...
    (0)
  • €8,28
  • + meer info
IBHRE CEPS EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS
  • IBHRE CEPS EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS

  • Tentamen (uitwerkingen) • 13 pagina's • 2024
  • Ohm's law equation - ANS V=IR EKG monitored patient should be __________, monitor chassis should be ___________ (nonconductive). Why - ANS ungrounded, grounded. Grounded patients would be able to conduct leakage currents. we don't want this lb to kg - ANS 2.2 lb = 1 kg F to C - ANS C=5/9(F-32) C to F - ANS F=9/5C+32 3 things that change automaticity of automatic cells - ANS 1. slope of phase 4 2. Change of threshold potential 3. Change of resting membrane pot...
    (0)
  • €12,67
  • + meer info
NSG 557 Cardiac Part 2 Exam Study Questions with 100% Correct Verified Answers
  • NSG 557 Cardiac Part 2 Exam Study Questions with 100% Correct Verified Answers

  • Tentamen (uitwerkingen) • 13 pagina's • 2024
  • Premature ventricular contractions, premature atrial contractions. Reentry Occurs when propagating impulse does not stop following normal activation of the heart, but persists and reexcites the heart after the refractory period Reentry - examples -Atrial Flutter -AVNRT -Scar-mediated VT (Ischemic CM, ARVC, Sarcoid)
    (0)
  • €12,43
  • + meer info
IBHRE CEPS - Trouble Questions with 100% correct answers
  • IBHRE CEPS - Trouble Questions with 100% correct answers

  • Tentamen (uitwerkingen) • 11 pagina's • 2024
  • 168. Compared to the the permanent pacemaker, does a temp pacer have constant current or voltage? Also, how much voltage can it generate? 5V or 20V? correct answersConstant current, 20V. (Doubles 9.5V) 171. Which patient with acute MI is most likely to need a temp pacer? Inferior MI, Mobitz I AV Bock Inferior MI, bundle branch block Anterior MI, Mobitz I AV Bock Anterior MI, bundle branch block correct answersAnterior MI, bundle branch block Acute BBB post MI should be seen as a warning...
    (0)
  • €15,59
  • + meer info
IBHRE CEPS 84 Questions Each With Correct And Verified Answers|2024
  • IBHRE CEPS 84 Questions Each With Correct And Verified Answers|2024

  • Tentamen (uitwerkingen) • 12 pagina's • 2024
  • 168. Compared to the the permanent pacemaker, does a temp pacer have constant current or voltage? Also, how much voltage can it generate? 5V or 20V? - ️️Constant current, 20V. (Doubles 9.5V) 171. Which patient with acute MI is most likely to need a temp pacer? Inferior MI, Mobitz I AV Bock Inferior MI, bundle branch block Anterior MI, Mobitz I AV Bock Anterior MI, bundle branch block - ️️Anterior MI, bundle branch block Acute BBB post MI should be seen as a warning and often pro...
    (0)
  • €7,79
  • + meer info
IBHRE CEPS - TROUBLE  EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)  A+ GRADED
  • IBHRE CEPS - TROUBLE EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) A+ GRADED

  • Tentamen (uitwerkingen) • 9 pagina's • 2024
  • 168. Compared to the permanent pacemaker, does a temp pacer have constant current or voltage? Also, how much voltage can it generate? 5V or 20V? - ANS Constant current, 20V. (Doubles 9.5V) 171. Which patient with acute MI is most likely to need a temp pacer? Inferior MI, Mobitz I AV Block Inferior MI, bundle branch block Anterior MI, Mobitz I AV Block Anterior MI, bundle branch block - ANS Anterior MI, bundle branch block Acute BBB post MI should be seen as a warning and often p...
    (0)
  • €12,67
  • + meer info
AAH practice test questions & answers 2024/2025
  • AAH practice test questions & answers 2024/2025

  • Tentamen (uitwerkingen) • 11 pagina's • 2024
  • AAH practice test questions & answers 2024/2025 The T Wave represents - ANSWERSventricular re-polarization If the heart is in a state of asystole - ANSWERSThere is no contraction What are the bipolar leads - ANSWERSI, II, and III The most common type of supraventricular Tachycardia is - ANSWERSAV nodal Reentrant tachycardia (AVNRT) In 2:1 AV block, the PR interval - ANSWERSLengthens In sinus arrhythmia, a gradual decreasing of the heart rate is usually associated with: - ANSW...
    (0)
  • €8,77
  • + meer info
IBHRE Study Material: GTP Trivia Questions and Answers 100% Solved
  • IBHRE Study Material: GTP Trivia Questions and Answers 100% Solved

  • Tentamen (uitwerkingen) • 17 pagina's • 2024
  • IBHRE Study Material: GTP Trivia Questions and Answers 100% Solved Most common form of SVT AVNRT AVNRT Characteristics 1. prolonged PR interval in the beat that starts reentry 2. HR: 150- 250 bpm 3. neck pounding, palpitations, light-headiness, near-syncope 4. narrow QRS 5. abrupt onset and termination of episodes 6. more common in women 7. frequently presents after age 20 rheobase the lowest point on a strength-duration curve at an infinitely long pulse duration chronaxie time pulse...
    (0)
  • €14,62
  • + meer info
IBHRE CEPS Exam Questions and Answers(RATED A)
  • IBHRE CEPS Exam Questions and Answers(RATED A)

  • Tentamen (uitwerkingen) • 22 pagina's • 2024
  • Ohm's law equation - ANSWER-V=IR EKG monitored patient should be __________, monitor chassis should be ___________ (nonconductive). Why - ANSWER-ungrounded, grounded. Grounded patient would be able to conduct leakage currents. we dont want this lb to kg - ANSWER-2.2 lb = 1 kg F to C - ANSWER-C=5/9(F-32) C to F - ANSWER-F=9/5C+32 3 things that change automaticity of automatic cells - ANSWER-1. slope of phase 4 2. Change of threshold potential 3. Change of resting membrane pote...
    (0)
  • €11,21
  • + meer info