[Show more]A fitting is a part of a wiring system that is intended primarily to perform which type of 
function? - mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the outside of a raceway, the length of the equipment bonding jumpe...
Preview 2 out of 15 pages
Add to cartA fitting is a part of a wiring system that is intended primarily to perform which type of 
function? - mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the outside of a raceway, the length of the equipment bonding jumpe...
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and 
retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than 
the air test. - B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
Every absorption...
Preview 3 out of 19 pages
Add to cartDefects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and 
retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than 
the air test. - B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
Every absorption...
An advantage of an electromagnet over a permanent magnet is that... - an electromagnet can 
be switched. 
An excellent diffuser surface is one that... - scatters light uniformly in all directions 
Light is converted into electricity... - in a photovoltaic cell 
The rotating part in a DC motor is kno...
Preview 2 out of 6 pages
Add to cartAn advantage of an electromagnet over a permanent magnet is that... - an electromagnet can 
be switched. 
An excellent diffuser surface is one that... - scatters light uniformly in all directions 
Light is converted into electricity... - in a photovoltaic cell 
The rotating part in a DC motor is kno...
1x sold
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 
70 amp load using THHM conductors. The minimum size conductors used our 
#_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 
3 
A 1 inch...
Preview 2 out of 10 pages
Add to cartThere are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 
70 amp load using THHM conductors. The minimum size conductors used our 
#_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 
3 
A 1 inch...
An advantage of an electromagnet over a permanent magnet is that ____. - An electromagnet 
can be switched on and off. 
An excellent diffuser surface is one that ____. - Scatters light uniformly in all directions. 
Light is converted into electricity ____. - In a photovoltaic cell. 
The rotating par...
Preview 2 out of 6 pages
Add to cartAn advantage of an electromagnet over a permanent magnet is that ____. - An electromagnet 
can be switched on and off. 
An excellent diffuser surface is one that ____. - Scatters light uniformly in all directions. 
Light is converted into electricity ____. - In a photovoltaic cell. 
The rotating par...
How many apprentices can a journeyman directly supervise? - 2 
When performing any service work on a customers heating system the licensee must notify the 
homeowner of? - Efficiency and code violations 
Can a licensed journeyman perform a cleaning on wood/oil combination unit without direct 
superv...
Preview 2 out of 13 pages
Add to cartHow many apprentices can a journeyman directly supervise? - 2 
When performing any service work on a customers heating system the licensee must notify the 
homeowner of? - Efficiency and code violations 
Can a licensed journeyman perform a cleaning on wood/oil combination unit without direct 
superv...
Grounding and Bonding: 
Where outside, aluminum or copper-clad aluminum grounding electrode conductors shall not be 
terminated within ____in. of Earth. 
A. 12 in. 
B. 18 in. 
C. 24 in. 
D. 36 in. 
- B. 18 in. 
250.64(A) 
Temporary Installations: 
When used by personnel during construction, remodeli...
Preview 3 out of 23 pages
Add to cartGrounding and Bonding: 
Where outside, aluminum or copper-clad aluminum grounding electrode conductors shall not be 
terminated within ____in. of Earth. 
A. 12 in. 
B. 18 in. 
C. 24 in. 
D. 36 in. 
- B. 18 in. 
250.64(A) 
Temporary Installations: 
When used by personnel during construction, remodeli...
where extensive metal in or on buildings or structures may become energized and is subject to 
personal contact _______ will provide additional safety. 
a) adequate bonding and grounding 
b) bonding 
c) suitable ground detectors 
d) none of these - a) adequate bonding and grounding 
single conductor...
Preview 2 out of 9 pages
Add to cartwhere extensive metal in or on buildings or structures may become energized and is subject to 
personal contact _______ will provide additional safety. 
a) adequate bonding and grounding 
b) bonding 
c) suitable ground detectors 
d) none of these - a) adequate bonding and grounding 
single conductor...
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - 
THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and 
conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet 
locations. 
Given: A one-...
Preview 3 out of 17 pages
Add to cartConductors with _____ marked on the insulation are NOT approved for use in a wet location. - 
THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and 
conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet 
locations. 
Given: A one-...
A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - c. Heavy 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in 
subsection (3), and individual other than an individual who is li...
Preview 3 out of 26 pages
Add to cartA fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - c. Heavy 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in 
subsection (3), and individual other than an individual who is li...
What table sizes bonding jumpers for for AC systems? - 250.102(C)(1) 
The NEC defines continuous load to be a load where max current on the circuit continues for at 
least how many hours? - Three 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many 
current ca...
Preview 2 out of 13 pages
Add to cartWhat table sizes bonding jumpers for for AC systems? - 250.102(C)(1) 
The NEC defines continuous load to be a load where max current on the circuit continues for at 
least how many hours? - Three 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many 
current ca...
Where a water pipe passes over an indoor motor control center, leak protection apparatus shall 
have a MINIMUM clearance of _____. 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to the water pipe - A: 6 feet to the pr...
Preview 2 out of 11 pages
Add to cartWhere a water pipe passes over an indoor motor control center, leak protection apparatus shall 
have a MINIMUM clearance of _____. 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to the water pipe - A: 6 feet to the pr...
1x sold
Where the outer sheath of Type MI cable is made of steel _____________. 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
B. a separate equipment grounding conductor shall be provided 
C. the grounding and grounded conductors shall be connected together 
D. it shall...
Preview 2 out of 13 pages
Add to cartWhere the outer sheath of Type MI cable is made of steel _____________. 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
B. a separate equipment grounding conductor shall be provided 
C. the grounding and grounded conductors shall be connected together 
D. it shall...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Preach. Stuvia facilitates payment to the seller.
No, you only buy this summary for R748,42. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
75323 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now