Created to serve as a complete, comprehensive code regulating the construction of single-family, two-family and buildings consisting of three or more townhouse units. - Answer IRC (International Residential Code)
Administrative - Answer First 2 chapters of code book are
True - Answer Plans or...
michigan builders license exam questions with corr
irc international residential code
Written for
Michigan builders license
Michigan builders license
3
reviews
By: micheal022106 • 5 months ago
By: robmcghan • 1 year ago
By: rachelschmidt • 1 year ago
Seller
Follow
Exampool
Reviews received
Content preview
Michigan Builders License Exam Questions With Correct Answers Created to serve as a complete, comprehensive code regulating the construction of single-family, two-
family and buildings consisting of three or more townhouse units. - Answer IRC (International Residential
Code)
Administrative - Answer First 2 chapters of code book are
True - Answer Plans or supporting documents are almost always required by the controlling authority prior to issuing a permit. T or F
Yes - Answer Does the building official have the authority to render interpretations of the code?
8 foot fence. - Answer None of the following require a permit, EXCEPT:
sidewalks and driveways tiling an 8 foot fence playground equipment
False - Answer Tables and illustrations are always supported by information found in the written code and footnotes. T or F
Live load. - Answer The amount of evenly distributed weight imposed by inhabitants, goods and removable objects on a floor or roof system is referred to as
True. - Answer If a code requirement is in the book, it is both acceptable and enforceable by the code official. T or F
Figures. - Answer Illustrations are typically referred to as Determine that buildings are built to the minimum enforceable standard. - Answer Generally speaking, the building official's job is to
True. - Answer It is required that all manufacturer instructions be at the jobsite at the time of inspection. T or F
Kitchen. - Answer All of the following are not considered habitable spaces EXCEPT:
bathrooms kitchens storage spaces closets
3. - Answer Bathrooms must be provided with an aggregate glazing area no less than _____ square feet, half of which must be openable.
44 inches. - Answer The maximum height of an egress window above the floor is
5.7 sq ft. - Answer A basement bedroom must have an egress window with a clear opening of at least ______ square feet.
3. - Answer At least one side-hinged exit door must be in each dwelling unit, and must be _____ feet wide.
30 inches. - Answer A porch more than _____ inches above grade must be provided with 36" guards.
200. - Answer Wall and ceiling finishes shall have a flame-spread classification of no more than ______ .
7 days. - Answer According to code, concrete must reach at least 70% of it's ability within ____________days. 40%. - Answer A stud used for a non-bearing partitions may not be notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - Answer The Michigan Uniform Energy code applies to new buildings as well as
U-factor. - Answer ___________ is a measure of how well the window or door assembly conducts heat. The lower the number, the better insulation the assembly will provide.
50%. - Answer Energy losses from recessed lighting fixtures can often reach ___% of the total thermal loss of a ceiling.
R-3. - Answer Michigan requires a minimum thermal resistance of ____________for mechanical system piping.
True. - Answer Oversized HVAC equipment has a higher initial cost, a higher operating cost, provides less comfort, and shorter life expectancy. T or F
Prescriptive Path. - Answer _______ is the compliance route that applies Table 402.1.1 to building envelope components, and is considered the most simple.
Area weighted averages. - Answer ___________ can be used to satisfy U-factor and SHGC requirements.
IC (Insulation Contact) - Answer Recessed lights must be _____ rated.
True. - Answer Up to 15 square feet of glazing per dwelling unit is exempted from U-value requirements. T or F
Registered design professional. - Answer The 2009 IECC requires a permanent certificate posted on the electrical distribution panel. The certificate shall be completed by the builder or State energy code requirements. - Answer One hurdle contractors face when bidding for an energy efficient project is choosing materials that fit the design, and also meet
False. - Answer Historically significant buildings are not exempt from code changes. T or F
R-value Settled thickness Manufacturer name - Answer Insulation products (blown and sprayed) must be documented with:
March 2011. - Answer The new Michigan codes took effect in
10. - Answer Below grade walls are insulated from the top of the basement wall down to _____ below grade, or the basement floor, whichever is less.
Area weighted average. - Answer The _______ is the combined Solar Heat Gain Coefficient of all the glazed fenestration products in the building.
Thermal insulation R-values Design criteria Equipment systems - Answer Plans and specifications must be detailed in regards to:
2009. - Answer In Michigan, the residential energy code is based on the _____ IECC, with certain amendments.
Air leakage. - Answer ___________ is the rate of air infiltration in the presence of a specific pressure differential.
Windows
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Exampool. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for R251,84. You're not tied to anything after your purchase.