Type ____ is multiconductor cable identified for use as underground service entrance cable. correct answersType USE cable
Knife switch rated for more than 1200 Amps at 250Volts or less correct answersCan be used only as isolating switch, shall not be opened under load
Track lighting with outl...
NYC MASTER ELECTRICIAN EXAM
Type ____ is multiconductor cable identified for use as underground service entrance cable. correct answersType USE cable
Knife switch rated for more than 1200 Amps at 250Volts or less correct answersCan be used only as isolating switch, shall not be opened under load
Track lighting with outlets in a bathroom is not allowed because ? correct answersTrack lighting has receptacle
Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided
with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system correct answers6 hours
Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall
be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. correct answers30 Amps
Where skin effect exist the ferromagnetic envelope shall be bonded at ____. correct answersBoth ends
GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. correct answersLocking
The maximum voltage drop from service point to the last over-current device in a dwelling unit? correct answers4%
Which of the following statements best describe the grounding requirement for central vacuum outlet correct answersAccessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system correct answersAre permitted
Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas correct answersDo not include
The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. correct answersExamined or treated
Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles correct answersSingle or two
A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients correct answersFour
Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer
on electronic equipment correct answersListed fitting
Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature correct answers3 inches
Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. correct answers6 ft
Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed correct answersGreen finish
Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating correct answersHexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-
amperes) or the nameplate rating, which ever is larger, for each dryer served ? correct answers5000 watts
Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____
windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. correct answers3 ft (36 inches)
—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing
installation is where there is no evidence of over-fusing or tampering. correct answersClass H
Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F correct answers3" inches
The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. correct answers8
In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? correct answersCombination range hood/microwave oven
Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment served.if ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the service or separately derived system disconnect correct answersIncluded in the manufactures instructions
Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? correct answersEVJ
Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed
correct answersType S fuse
Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a lesser distance is permitted by and exceptions correct answers8'ft
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller QUILLSKY. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for R306,72. You're not tied to anything after your purchase.