100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions R277,37   Add to cart

Exam (elaborations)

Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions

1 review
 220 views  2 purchases
  • Course
  • Gas Fitter 2
  • Institution
  • Gas Fitter 2

Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions A room heater installed in either a sleeping area or public area shall be: A. direct vent only B. equipped with a regulator C. equipped with a fan D. equipped with an on / off switch on the wall Correct Answer: B What ...

[Show more]

Preview 4 out of 60  pages

  • September 17, 2023
  • 60
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • Gas Fitter 2
  • Gas Fitter 2

1  review

review-writer-avatar

By: kodiarchbold • 9 months ago

avatar-seller
Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions A room heater installed in either a sleeping area or public area shall be: A. direct vent only B. equipped with a regulator C. equipped with a fan D. equipped with an on / off switch on the wall Correct Answer: B What type of vent must be used when the vent of a wall furnace will be concealed in a partition wall? A. B vent B. L vent C. BH vent D. BW vent Correct Answer: D Single wall vent connector s: A. may pass through floors, ceilings or roofs provided a metal thimble is used B. may pass through floors, ceilings or roofs provided the required minimum distance from combustible material is maintained C. may pass through floors, ceilings or roofs pro vided they are insulated D. shall not pass through floors, ceilings or roofs Correct Answer: D BW vent shall be used only with an approved: A. decorative appliance B. down flow furnace C. revertible flue boiler D. recessed wall furnace Correct Answer: D What must be done during the installation of a gas log fireplace? A. Make sure there is a metal mesh screen in front of the fireplace B. Secure the chimney damper in the open position C. Install a pressure regulator D. Install a metal chimney liner Correct Answer: B When can a certified hose be used to connect a construction heater to temporary piping? A. Only if a lever handle shut off valve is installed upstream of the hose B. Only if the hose is 15 feet long C. Ne ver Correct Answer: A Which of the following is acceptable when a fireplace insert is installed? A. A metal chimney linear B. The existing fireplace flue C. BW vent D. A tile lined fireplace flue? Correct Answer: A An unvented infra -red heater can be ins talled in ________ application A. A warehouse B. A commercial building C. An industrial building D. All of the above Correct Answer: D Dirt pockets are required on: A. Decorative appliances B. Gas logs C. Room heaters D. None of the available choices Co rrect Answer: D What diameter and length of a dirt pocket is required when a drop line is 3 -inch diameter? A. 3 inch diameter by 3 inches long B. 1 inch diameter by 3 inches long C. 3/4 inch diameter by 3 inches long D. 2 inch diameter by 3 inches long Correct Answer: D What type of room heater maybe installed in a bathroom? A. Natural draft B. Direct fired C. Forced draft D. Direct vent Correct Answer: D What safety control protects a steam boiler if the condensate pump fails to return water to the boiler? A. High pressure limit control B. Low pressure limit control C. Flame safeguard control D. Low water cut off Correct Answer: D The relief valve for a residential low -pressure hot water boiler system should be? A. 14.7 psia B. 15 psia C. 30 psig D. 30 psia Correct Answer: C A backflow prevent used in a boiler system should be located in the: A. Over flow line connected to the drain B. Return line close to the boiler C. 1/4" line connecting the boiler and cushion t ank D. Make up water line to the system Correct Answer: B Automatic chlorinators must be installed: A. upstream of the heater B. downstream of the heater C. upstream of the filter D. downstream of the filter Correct Answer: B On seasonal start up, a pool heater should run: A. intermittently B. continuously for 24 hours C. continuously until the thermostat is satisfied D. one hour on and one hour off until the thermostat is satisfied Correct Answer: C Before lighting a burner i n a steam boiler, ensure that: A. there is water in the boiler B. the temperature controller is set properly C. the main burner test firing valve is turned on D. the safety valves are open Correct Answer: A The recommended water temperature setting from a mixing valve to the domestic water system in combination heating systems that employ oil -fired water heaters for heating potable water and for space heating is: A. 43°C (110°F) B. 49°C to 54°C (120°F to 130°F) C. 60°C to 66°C (140°F to 150°F) D. 83°C (180 °F) Correct Answer: B An inverted sensor (measures water level) can be found operating what type of appliance? A. Hot water boiler B. Steam water boiler C. Domestic hot water storage tank D. Domestic potable hot water tank Correct Answer: D A backflow prevent used in a hydronic heating system is used to: A. Keep hot water from entering the cold water system B. Hold the pressure on the system during a temporary shutdown to prevent the entry of air C. Prevent the heating water from circulating the wrong way in the system D. Keep non -combustible water from entering the drinking water system Correct Answer: D A low water cut off device on an automatically fired hot water heating boiler rated at 350,000 Btuh (102 kW) is: A. Not required if a limit control is installed B. Not required if it is installed in the industrial application C. Required when any portion of the circulating system is located below the boiler D. Required only in commercial applications Correct Answer: C A pressure reducing va lve A. Relieves system pressure in excess of the set pressure B. Reduces the city main pressure to a safe working pressure C. Reduces the working pressure to the city main pressure D. Prevents hot water gravity circulation Correct Answer: B The maximum o perating pressure of a low pressure steam boiler is A. 5 psig (35kPa) B. 15 psig (100 kPa) C. 100 psig (690 kPa) D. 150 psig (1035 kPa) Correct Answer: B A scotch marine boiler is what type of boiler? A. Two pass boiler B. Copper tube boiler C. Fire tube boiler D. Four pass water tube boiler Correct Answer: C A fire tube boiler has: A. Water outside the tube and flue gases outside B. Water inside the tubes and flue gasses outside C. Water inside the tubes and water outside D. Water outside the tubes and flue gases inside Correct Answer: D Why is a pressure relief valve installed on a pool heater system? A. To maintain the pool water level B. To prevent over pressurizing the filter C. To prevent damage to the system D. To re lieve excess water pressure caused by solar gun Correct Answer: C When does an electrically operated automatic vent damper on a mid -efficiency furnace open? A. Before the ignition cycle B. When the furnace is hot C. At the same time as the gas comes on D. When the main switch is turned on Correct Answer: A What is the minimum distance the vent of a Category 4 furnace with an input under 100,000 Btuh can terminate from a combustion air inlet of any other appliance? A. 12" B. 36" C. 60" D. 120" Correct An swer: A

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nipsey. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for R277,37. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75323 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Start selling

Recently viewed by you


R277,37  2x  sold
  • (1)
  Buy now