The minimum amp circuit breaker that should be used to protect a 120V water heater circuit with a 1600-watt element would be rated at ________ amps
15
When testing for excessive EMF emission near a conductor or appliance, the tool o...
iyrs electrical abyc exam questions and answers gr
the minimum amp circuit breaker that should be use
when testing for excessive emf emission near a con
what material is recommended for clamping condu
Written for
Abyc
Abyc
Seller
Follow
Dreamer252
Reviews received
Content preview
IYRS Electrical ABYC Exam Questions
and Answers Graded A+
The minimum amp circuit breaker that should be used to protect a 120V water heater
circuit with a 1600-watt element would be rated at ________ amps - answer15
When testing for excessive EMF emission near a conductor or appliance, the tool of
choice is a - answer Gauss Meter
The primary problem with using a series circuit to supply multiple loads is that - answer
voltage drop across each load will be excessive
the most common electrical circuit problem in marine applications is - answer unwanted
open
the primary by-product of excessive electrical resistance is - answer heat
the tool of choice today for tracing shorted and open circuits is the: - answer TDR
What material is recommended for clamping conductors over engines and moving
machinery according to the ABYC - answer Metal
according to ABYC acceptable minimum clearance for routing wire near a dry exhaust
section is - answer9 inches (225 mm)
The maximum number of terminals allowed to be attached to any one terminal stud
based on ABYC is - answer4
How much current should flow through the
DC grounding conductor in a 25-amp DC motor circuit - answer0 amps
conductors of #10 AWG and larger shall be permitted to be connected in parallel
______ - answerWhere the ampacity of each individual conductor is sufficient to carry
the entire load current shared by the parallel conductors
A technician is installing the cable run from the batteries to the main DC panelboard on
a boat aspart of a refit. The boat has a 12-volt system, and the distance from the panel
to the batteries is 15 ft (approximately 3 m).The maximum current draw from the panel
is calculated at 90 amps.What gauge cable should be used at a minimum to maintain
Standards compliance? - answer0 AWG
, 8. DC grounded conductors on new boats that are also equipped with AC systems
should use _________ insulation. - answeryellow
the maximum spacing for cable run support based on ABYC is - answer16 inches (400
mm)
the smallest gauge cable allowed for unsheathed wire runs through the boat is -
answer16 AWG
The maximum sustained charging voltage acceptable to some gel cell battery
manufacturers is - answer14.1
Sheathed, ungrounded conductors connected directly to a battery must have
overcurrent protection devices located within _______ of connection to the battery -
answer40 Inches
on a battery where a hydrometer can be used, a cell reading of 0.050 points of a
specific gravity below all of the other cells in the battery may indicate - answerA bad cell
and battery replacement needed
some battery manufacturers will only consider replacement on batteries whose
condition has been determined by use of a - answerconductance tester
Tech A says that sealed batteries can be mounted anywhere in the boat where space
can be found.TechBsays that consideration should be given to ventilation and the
mounting surfaces and the surrounding area near the battery, and their resistance to
acid attack.Which technician is correct? - answertech B
Minimum battery reserve capacity allowed based on ABYC standards is - answer90
Minutes
Based on ABYC standards, cable attachment to batteries with wing type nuts is allowed
as long as the wire gauge does not exceed - answer8 AWG
Traditional battery load testing methods dictate that a load equivalent to _____ % of the
battery's CCA rating be placed on the battery - answer100
The metallic case of the battery charger should be connected to the - answerDC
grounding system
Tech A says that voltage supplied to the rotor controls alternator output voltage. Tech B
says that the alternator output is proportional to rotor voltage. Which Technician is
correct? - answerBoth Techs
A voltage regulator controls which of the following? - answerAlternator field Voltage
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Dreamer252. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for R326,14. You're not tied to anything after your purchase.