DoD Fire Inspector I Questions and
Answers 100% Solved

Commercial Publications for Fire Inspector includes: - answer National Fire Code
Life Safety Code Handbook
IFSTA Manuals

Tools to always bring with you on an inspection are.. - answer..tape measurer (50ft),
clipboard, flashlight, notebook and a camera

What is the difference between UFC 3-600-1 and DoD Instruction 6055.06? -
answerUFC: fire codes/standards adopted by all DoD departments
DoD: establishes the foundation for prevention and education

Dry Pipe sprinkler systems that hold 500 gallons or more.. - answer..must be equipped
with a quick-opening device unless the most remote location of the structure can be
reached with water within 60 seconds

Sprinklers can be activated by detectors or.. - answer..mechanically, hydraulically or
pneumatically

What three types of sprinklers are there? - answerPendant(most common), upright and
sidewall

The orifice size dictates.. - answer..how much water flow will come out of the sprinkler

What detects the presence of a suspected fire? - answerAn actuator in a dry chemical
system (NFPA 17)

Standpipes have a total of three classes.. - answer..Class I: regular connection
Class II: pre connected hose for occupants
Class III: combo with a separate connection for class I

What two components are required for a fire alarm system? - answerA detection device
and a notification appliance

What smoke detector contains small amounts of radiation? - answerIonization smoke
detector

How to determine gross floor area (square footage) - answerW x H

, Net floor area - answerSubtract all fixed objects

Occupant load - answerGA/NA divided by code

Door openings are required to have a clear width of - answer..no less than 32 inches

The elevation on both sides of a door.. - answer..shall not vary by more than 1/2 an inch

Panic hardware must be installed on a door - answerBetween 34-48 inches from the
floor level

Panic hardware cannot exceed - answer15 lbs of force

Panic hardware must extend across the door - answerNo less than 1/2 the size of the
door

Minimum stairway width is.. - answer..44 inches, existing is 36 inches

Handrail height is.. - answer35 inches for an acceptable height

Emergency lighting is to be tested.. - answer..monthly for 30 seconds with a required
interval of 3-5 weeks at a time in-between tests

Emergency lighting must stay lit for - answer1-1/2 hours in the event the normal system
fails

Travel distance is measure by the - answerWalking surface, along the centerline of the
natural path of travel

Two items to be inspected in an air conditioner are.. - answer..the smoke detectors and
the dampers

Spare sprinklers must be kept on the premises. - answerAt least six for systems with
less than 300

The maximum travel distance for a class K extinguisher - answerCannot exceed 30 feet
(extinguisher)

Extinguishers that require 12 year hydrostatic tests must.. - answer..be emptied every 6
years

Requirements for a fire lane.. - answer20 feet of width
13'6" vertical clearance
No parking painted

To calculate hydrant flow - answerGPM=29.83 x Cd x d2 x Psquared

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?