Journeyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesWhat must you do if you notice code violations in a homeowners house? - ANSWER-Notify them and recommend ways to a...
What must you do if you notice code violations in a homeowners house? -
ANSWER-Notify them and recommend ways to address them
What must be done when performing an annual tune-up on a heating
system? - ANSWER-A combustion efficiency test and a copy must be posted
on site
Whenever a furnace, direct fired hot water heater, or boiler is installed the
total installation must be brought into compliance with what requirements
BEFORE appliance can be fired? - ANSWER-NFPA 31
When an emergency arises that does not allow adequate time to get a
chimney lined/and or repaired before installing the new heating appliance
the licensee may defer the required repairs for how long? - ANSWER-90 days
,What must be performed before a new installation? - ANSWER-A heat loss
system design and load calculation. A copy must be retained to be presented
upon request of board inspector
What may be installed in the supply line but not a return line? - ANSWER-A
check valve
If the low water cut off is not installed directly in the boiler where may it be
installed? - ANSWER-Main supply line (vertical riser) as close to boiler as
possible, or in a water column of continuous piping attached directly to the
boiler
A listed lever or wheel thermally operated oil shut off valve must be installed
where? - ANSWER-At the burner and the oil supply tank
When outside tanks are used a thermally operated shut off valve must be
installed where? - ANSWER-The supply line enters the inside of the building
and where the oil line enters the room where the appliance is located
,When inside tanks are used and the oil supply tank is installed in a separate
room, a thermally shutoff valve must be installed where? - ANSWER-Where
the line enters the room where the appliance is located
All copper oil supply and return lines must be encased in a continuous piece
of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing.
The end of the conduit shall not exceed how far from any connection except
the connection at fuel tank? - ANSWER-2 inches
All oil fired BOILERS must be provided with a properly installed and operating
what? - ANSWER-Low Water cut off
Where shall a low water cutoff be installed? - ANSWER-At the level
recommended by the manufacture, but in no case below the crown sheet
Whenever the oil supply is taken from the top of an oil tank a thermally
operated wheel or lever type shut-off valve must be installed where? -
ANSWER-At the tank and at the burner
, In order to avoid undetected oil leaks under floors, the conduit must be how
much bigger than the supply and return lines? - ANSWER-One pipe size
larger
An oil supply line that penetrates a foundation wall must be what? -
ANSWER-Sealed
What must coated copper tubing have installed at the tank when used
underground? - ANSWER-Oils Safety Valve or PRV
When an oil filter or other accessory equipment is connected to a copper
piping smaller than 3/4 "and is not directly connected to the oil tank or
burner the filter or other device must be what? - ANSWER-Rigidly supported
by wall or floor mounted brackets
What must supply and return lines be connected with? - ANSWER-Flare
fittings
What fittings shall not be used unless for introduction of lines at top of the
tank with a single or double tap bushing? - ANSWER-Compression fittings
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through EFT, credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller NursingTutor1. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for R272,71. You're not tied to anything after your purchase.